Construction features

ARMOURED MULTICORE HIGH TEMPERATURE CABLES

  • Nature of conductor: Nickel-plated copper or pure nickel.
  • Insulation: successive tapes of siliconised glass fibre + glass fibre braid.
  • Gathering: short pitch.
  • Armour: galvanised steel or tinned copper braid or stainless steel.
Operating parameters:
  • Continuous serving temperature:
    • for nickel-plated copper conductor: -60°C to +280°C.
    • for pure nickel conductor: -60°C to +350°C.
  • Static bending radius: 12 x cable outer diameter.
Electrical characteristics:
  • Rated voltage: 300/500 V
  • Test voltage: 3000 V

  

Options

  • Armour with options:
    • Galvanised steel braid
    • Tinned copper braid
    • Stainless steel braid
  • Upon customer request UL approved STYLE 5168 (+250°C / 500V)

Use

  • Plastic Machine Builders.
  • Resistance builders.
  • Feeding industrial ovens.
  • The armour braid protects the cable from falling molten or glowing plastic material.

Technical specifications

Service temperature
Nickel-plated Copper Conductor -60°C +280°C - Pure Nickel Conductor -60°C +350°C
Nominal tension
300/500V
Test voltage
3000V
Bending Radius Static
12 x cable outer Ø