Construction features

- Tinned copper conductor - class 5 - EN 60228.
- Separator tape (optional).
- Elastomer Fire resistant - type EI 109 according to EN 50264-3-2.
- Tinned Copper Braid.
- Fire resistant elastomer - type EM 104 to EN 50264-3-2.

 

Continuous service temperature: -40 °C to +90 °C

Electrical characteristics:

  • Rated voltage: 1300/500V
  • Test voltage: 2kV A.C.

Mechanical characteristics:

  • Shear resistance: ★★★★★
  • Abrasion resistance: ★★★★☆
  • Minimum internal bending radius (EN 50355): 10xD

Chemical characteristics:

  • Acid and basic resistance: ★★★★☆
  • Resistance to mineral oils: ★★★★☆
  • Fuel resistance only for M-class: ★★★★☆

Standards and approvals

  • EN 60228, EN 50264-1, EN 50264-3-2.
  • EN 50267-2-1, EN 50267-2-2.
  • EN 60332-1-2, EN 60332-3-24, EN 61034-2.

FIRE-SMOKE

  • Halogen-free (EN 50267-2-1).
  • Low toxicity (EN 50267-2-2).
  • Low smoke (EN 61034-2).
  • Flame retardant (EN 60332-1-2, EN 60332-3-24).

Options

  • Other nominal sections on request: consult us

Technical specifications

Service temperature
-40°C +90°C
Nominal tension
300/500V
Test voltage
2 KV BC.