Construction features

Cable composition:

  • Tin-plated copper conductor - class 5 - EN 60228.
  • Separator tape (optional).
  • Elastomer Fire resistant - type EI 109 according to EN 50264-3-1.
Continuous service temperature: -40°C to +90°C

Electrical characteristics:

  • Rated voltage: 1.8/3 kV
  • Test voltage: 6.5 kV A.C.

Mechanical characteristics:

  • Shear resistance: ★★★★★
  • Abrasion resistance: ★★★★☆
  • Minimum internal bending radius (EN 50355): 4xD
Chemical characteristics:
  • Acid and basic resistance: ★★★★☆
  • Resistance to mineral oils: ★★★★☆
  • Fuel resistance only for M-class: ★★★★☆

Standards and approvals

  • EN 60228, EN 50264-1, EN 50264-3-1.
  • EN 50267-2-1, EN 50267-2-2.
  • EN 60332-1-2, EN 60332-3-24, EN 61034-2.
  • NF F 16-101.
Fire-smoke
  • Halogen-free (EN 50267-2-1).
  • Low toxicity (EN 50267-2-2).
  • Low smoke (EN 61034-2).
  • Flame retardant (EN 60332-1-2, EN 60332-3-24).
  • Fire-smoke protection (NF F 16-101, BS 6853, IEC 11170-3, DIN 5510-2, EN 45545-2, NFPA 130).

Options

  • other nominal sections on request

Technical specifications

Service temperature
-40°C +90°C
Nominal tension
1.8/3 kV
Test voltage
6.5 kV