Construction features

Halogen-Free ARMED Fire-Resistant Naval Cable

Service temperature: -30°C to +80°C
  • Maximum conductor temperature: +95°C
  • Maximum short-circuit conductor temperature: +250

Minimum bending radius: 6 x D

  • Conductor: Red copper - Class 2 according to IEC 60228
  •  Insulation: Fire-resistant elastomer
  • Separator tape
  • Armour: Red Copper Braid
  • HFFR compound outer sheath, type SHF1
Electrical characteristics:
  • Rated voltage: 600/1000V
  • Test voltage: 3500V
Standard production:
  • Outer sheath: orange
  • Identification of conductor colours: see specification
  • Outer mark - MULTIMAX CF BL 331 0.6kV
    95C IEC 60331- (120) IEC 30332-3-22

Respected standards

Standards and approvals

  • Fire resistant according to IEC 60331-1 or IEC 60331-2: 120 minutes.
  • Not fire propagating according to IEC 60332-3-22.
  • Flame-retardant according to IEC 60332-1-2.
  • Halogen-free according to IEC 60754-1.
  • Non-corrosiveness of smoke according to IEC 60754-2.
  • Low opacity of fumes emitted according to IEC 61034.
  • Dimensions according to IEC 60092-353.
  • Production and testing according to IEC 60092-350.
  • BVM certification.

Options

  • Flex Series - Class 5 tinned copper conductor according to IEC 60228 + braided tinned copper armour.
  • Outer sheath made of cross-linked HFFR compound, type SHF2.

Use

  • Fixed installation on board ship
  • Wiring of fire detection control systems - detection fire

Packing

Hanks, reels cardboard drums

Technical specifications

Service temperature
-30°C to +80°C
Peak temperature
+95°C
Nominal tension
600/1000 V
Test voltage
3500 V
Reaction to Fire
IEC 60331-21
Bending Radius Static
6 x cable Ø ext.