HALOGEN-FREE - INSTRUMENTATION CABLE FOR NAVY USE
MULTIMAX CI BL 331 FIXED INSTALLATION ON BOARD SHIP IEC 60092-350 AND IEC 60092-376
FIRE RETARDANT STANDARD 60332-3-22 - FIRE RESISTANT STANDARD IEC 60331-21
FLAME-RETARDANT STANDARD 60332-1
Wiring of fire detection control systems - detection fire
Wiring of fire detection control systems - detection fire
1 Red copper conductor class 2, IEC 60092-376
2 Fire-resistant elastometer
3 Polyester tape
4 Aluminium/Polyester tape with drainage wire
5 Armour: red copper braid with3continuous wire for EG and EI
6 SHF1 Polyolefin Sheathing
- Halogen-free according to IEC 60754-1
- Fire resistant according to: IEC 60331-21
- Fire-retardant according to IEC 60332-3-22
- Flame-retardant according to IEC 60332-1
- Non-corrosiveness of smoke according to IEC 60754-2
- Low smoke opacity : IEC 61034
- BVM certification
FLEX Series Conductor
Class 5 tinned red copper and tin-plated copper armouring
Individual shield (EI) red copper braid with continuity wire
Fixed installation on board ship manufacture and testing according to IEC 60092-350 and IEC 60092-376
Hanks, reels
Service temperature-30°C to +80°C
Peak temperature+95°C
Nominal tension150/250 V
Test voltage1500 V
Bending Radius Static8 x cable outer Ø