Construction features

HALOGEN-FREE - INSTRUMENTATION CABLE FOR NAVY USE

MULTIMAX CI BL 331 FIXED INSTALLATION ON BOARD SHIP IEC 60092-350 AND IEC 60092-376
FIRE RETARDANT STANDARD 60332-3-22 - FIRE RESISTANT STANDARD IEC 60331-21
FLAME-RETARDANT STANDARD 60332-1
Wiring of fire detection control systems - detection fire

Wiring of fire detection control systems - detection fire

1 Red copper conductor class 2, IEC 60092-376
2 Fire-resistant elastometer
3 Polyester tape
4 Aluminium/Polyester tape with drainage wire
5 Armour: red copper braid with3continuous wire for EG and EI
6 SHF1 Polyolefin Sheathing

Respected standards

Standards and approvals

- Halogen-free according to IEC 60754-1
- Fire resistant according to: IEC 60331-21
- Fire-retardant according to IEC 60332-3-22
- Flame-retardant according to IEC 60332-1
- Non-corrosiveness of smoke according to IEC 60754-2
- Low smoke opacity : IEC 61034
- BVM certification

Options

FLEX Series Conductor
Class 5 tinned red copper and tin-plated copper armouring
Individual shield (EI) red copper braid with continuity wire

Use

Fixed installation on board ship manufacture and testing according to IEC 60092-350 and IEC 60092-376

Packing

Hanks, reels

Technical specifications

Service temperature
-30°C to +80°C
Peak temperature
+95°C
Nominal tension
150/250 V
Test voltage
1500 V
Bending Radius Static
8 x cable outer Ø