Construction features

ARMED and Halogen-free naval cable

Continuous service temperature: -30°C to +80°C
  • Maximum conductor temperature: +90°C
  • Maximum short-circuit conductor temperature: +250°C

Minimum bending radius: 8 x D

  • Red copper conductor, class 2 according to IEC 6009-376
  • Insulation: cross-linked polyethylene, type HF XLPE
  • Electrical screen: aluminium/PET tape + continuity wire
  • Separator tape
  • Armour: red copper braid (EG and EI with continuity wire)
  • Outer sheath: HFFR compound type SHF1
Electrical characteristics:
  • Nominal voltage: 150/250V
  • Test voltage: 1500V
Standard production:
  • Outer sheath: grey
  • Identification of conductor colours: see technical specification
  • Outer mark - MULTIMAX 150/250V
    90C IEC 60332-3-22

Respected standards

Standards and approvals

  • Not fire propagating according to IEC 60332-3-22.
  • Flame-retardant according to IEC 60332-1-2.
  • Halogen-free according to IEC 60754-1.
  • Non-corrosiveness of fumes according to IEC 60754-2.
  • Low opacity of smoke emission according to IEC 61034
  • Production and testing according to IEC 60092-376 and IEC 60092-350.
  • BVM certification

Options

  • FLEX Series: Flexible tinned copper conductor Class 5 according to IEC 60092-376 and tinned copper braided armour
  • External sheathing in cross-linked HFFR compound, type SHF2 (BVM-certified)

Use

Fixed installation on board ship construction and testing according to IEC 60092-350 and IEC 60092-376

Technical specifications

Service temperature
-30°C to +80°C
Peak temperature
+90°C
Nominal tension
150/250 V
Test voltage
1500 V
Bending Radius Static
8 x cable outer Ø