Construction features

Multi-core cable - Halogen-free

Continuous service temperature: -60°C +300°C

The cable has an excellent resistance to ageing and good resistance to thermal shocks 

  • Conductor: Red Copper - Class 5 - IEC 60228
  • Insulation: Silicone-impregnated glass fibre complex
  • Siliconised Glass Fibre Braid
  • Optional Separator Tape
  • Siliconised Glass Fibre Braid
Electrical characteristics:
  • Rated voltage: 300/500V
  • Test voltage: 3000V
Standard production:
  • Standard conductor colours: see table
  • Standard external braid colour: grey or black
  • Some cables may have a separator tape under the outer braid

 

Standards and approvals

  • Halogen-free: IEC 60754-1 / EN 50267-2-1.
  • Resistance to vertical flame propagation on insulated cable: IEC 60332-1-2 / EN 50265-2-1 / NF C 32-070 test C2.

Options

  • Tinned or nickel-plated copper conductor: consult us.
  • Flexible outer armouring:
    >Galvanised steel braid (ref. MHR BG): consult us.
    >Stainless steel braid (ref. MHR BI): consult us.
  • Electric screen:
    >Red, tinned or nickel-plated copper braid: consult us.
    >Aluminium tape + continuity wire: consult us.
  • Other conductor numbers: consult us.
  • Other nominal sections: consult us.
  • Other colours: consult us.
  • Other options and/or combinations: consult us.

Use

  • Hot atmosphere wiring up to 280°C
  • Wiring in the metal industry, glass processing, ...
  • Wiring of industrial ovens and stoves, thermoplastic processing machines, welding machines
  • Cartridge heaters, heating plates and colliers

 

Packing

cardboard hanks, reels or drums

Technical specifications

Service temperature
-60°C +300°C
Peak temperature
+350°C
Nominal tension
300/500V
Test voltage
3000V
Bending Radius Static
8 x cable outer Ø