Construction features

Continuous service temperature: 60°C +180°C

The medium voltage cable has good resistance to thermal shocks and the UV radiation and an excellent mechanical resistance 

  • Flexible tinned copper conductor - class 5 according to IEC 60228
  • Optional separator tape
  • Insulation: special silicone rubber
  • Reinforcement: Fibreglass braid
Electrical characteristics:
  • Rated voltage: 1.1 kV
  • Test voltage: 3.5 kV
Standard production:
  • Standard insulation colour: white
  • Standard colour of reinforcement braid: yellow
  • Outer mark: SILICOUL 1.1 KV -
    .
  • No external mark for 1.5 mm sections2

Respected standards

Standards and approvals

  • Smoke emission F1 according to NF F 16-101
  • Bureau VERITAS Certificate of Approval: compliance with tests described according to IEC standards
    • IEC 60092-350/353/360,
    • IEC 60228,
    • IEC 60331-11/21,
    • IEC 60332-1-1/2,
    • IEC 60332-3-22
    • IEC 60754-2.
  • Lloyd's Register approval certificate: compliance with tests described according to standards
    • IEC 60228
    • IEC 60092-350/353/360
    • IEC 60754-2
    • IEC 60332-1-1/2,
    • IEC 60332-3-22 category A
    • IEC 60331-11/21

 

Options

  • Option UL/CSA 1.1KV APPROVAL ref. STYLE 3661
  • Other nominal voltages : SILICOUL® 3.7KVSILICOUL® 6.6KVSILICOUL® 13.8KV
  • Extra-flexible tinned copper conductor - class 6 according to IEC 60228: consult us
  • Flexible or extra-flexible conductor in red, silver-plated or nickel-plated copper - class 5 or 6 according to IEC 60228: consult us
  • Without reinforcement braid (ref. SILICOUL® ST 1.1 KV): consult us
  • High temperature fibre reinforcement braid: consult us
  • Flexible outer armouring:
    • Galvanised steel braid (ref. SILICOUL® BG 1.1 KV): Consult us
    • Stainless steel braid (ref. SILICOUL® BG 1.1 KV): Consult us
  • Electrical shielding in tinned copper possible
  • SILICOUL® 1.1 KV multicore cable assembly: consult us
  • Other external brands: consult us
  • Other colours: consult us
  • Other nominal sections: consult us
  • Other options and combinations of options: consult us

Use

  • Internal wiring of electric motors, where high cut and abrasion resistance is required, transformers and electrical machines
  • Wiring of static machines
  • Shipbuilding and railways
  • Switchboards

Packing

Hanks and reels.

Technical specifications

Service temperature
60°C to +180°C
Nominal tension
1.1KV
Test voltage
3.5KV