General characteristics:
- Good resistance to acids.
- Fairly good resistance to bases.
- Good resistance to mineral oils in IRM 902
- Good resistance to aliphatic hydrocarbons
- Water resistance: type AD7 according to IEC 60529 without immersion of the ends
- UV resistance ≥ 2 000 hours according to EN 16472
Thermal characteristics:
- Continuous service temperature: -60°C to +200°C
Electrical characteristics:
- Tensione nominale: 600/1000 V.
- Test voltage: 3500 V.
- IEC 60228 / NF C 32-090. IEC
- IEC 60332-1 / IEC 60332-3 / NF C 32-070 test C1
- IEC 60331-21 / NF EN 50200
- IEC 61034-2 / IEC 60754-1 / IEC 60754-2
Fire and smoke behaviour:
- Non propagante la fiamma – cavo da solo: EC 60332-1-2 / NF EN 60332-1-2 / NF C 32-070 test C2.
- Non propagante la fiamma – cavi raggruppati: IEC 60332-3-22 cat. A/ NF EN 60332-3-22 cat. A.
- Non propagatore dell’incendio: NF C 32-070 test C1
- Fire resistant: IEC 60331-21/ NF EN 50200
- Low smoke density: IEC 61034-2 / NF EN 61034-2.
- Halogen-free: IEC 60754-1 / NF EN 60754-1.
- Low corrosivity of emitted gases: IEC 60754-2 / NF EN 60754-2
- FLEX: conduttore flessibile in rame stagnato, classe 5 secondo IEC 60228
- Altri conduttori: consult us
- ATEX according to NF C 15-100 Part 4-42/ EN 60079-14
Particolarmente adatto per le installazioni fisse in ambiente con potenziale esplosivo, eccetto modalità di protezione di sicurezza intrinseca “i”
o ENERSYL® HT BG EX POWER: con una guaina in silicone sotto l’armatura e senza nastro separatore igroscopico
Particolarmente adatto per le installazioni fisse in ambiente con potenziale esplosivo, eccetto modalità di protezione di sicurezza intrinseca “i”
Service temperature-60°C to +200°C
Nominal tension600/1000V
Test voltage3500V