The cable has a good resistance to acids, bases and excellent resistance to aliphatic hydrocarbons.
It also has:
- Water resistance: type AD7 according to IEC 60529 without immersion of the ends
- UV resistance ≥ 2 000 h according to EN 16472.
Thermal characteristics:
- Continuous service temperature: -30°C to +80°C.
- Maximum conductor temperature: +90°C
Electrical characteristics:
- Rated voltage: 600/1000V
- Test voltage: 3500 V.
Standard production:
- Sheath: brick red
- Insulation: black
- IEC 60332-1 / IEC 60332-3 / NF C 32-070 test C1
- IEC 60331-21 / NF EN 50200
- IEC 61034-2 / IEC 60754-1 / IEC 60754-2.
- IEC 60228 / NF C 32-090
Fire and smoke behaviour:
- Flame-retardant - on single cable: IE 60332-1-2/ NF EN 60332-1-2 / NF C 32- 070 test C2.
- Flame-retardant - on cable bundle: IEC 60332-3-22 cat. A / NF EN 60332-3-22 cat. A
- Non-combustible: NF C 32-070 test C1
- Fire resistance: IEC 60331-21 / NF EN 50200
- Low smoke density: IEC 61034-2 / NF EN 61034-2
- Halogen-free: IEC 60754-1 / NF EN 60754-1
- Low corrosivity of emitted gases: IEC 60754-2 / NF EN 60754-2
- FLEX: flexible tinned copper conductor, class 5 according to IEC 60228
- Other colours: consult us
- Cable at 105°C: consult us
- ATEX according to NF C 15-100 part 4-42/ EN 60079-14 Particularly suitable for fixed installations in explosion hazardous areas, without intrinsic protection mode “i” - ENERSYL® FR BG EX POWER : with HFFR sheathing under the armouring and without hygroscopic separator tape
Service temperature-30 °C to +80 °C.
Peak temperature+90°C
Nominal tension600/1000V
Test voltage3500V