Construction features

Continuous service temperature: -60°C +180°C

The cable has an excellent mechanical resistance and good resistance to thermal shocks and the UV radiation

  • Flexible tinned copper conductor - class 5 according to IEC 60228
  • Separator tape (optional)
  • Insulation: special silicone rubber
  • Reinforcement: Synthetic fibre braid
Electrical characteristics:
  • Rated voltage: 7.2 kV
  • Test voltage: 15 kV
Standard production:
  • Standard insulation colour: white
  • Standard colour of reinforcement braid: grey

Style 3663

 

Respected standards

Standards and approvals

  • UL approval (180 °C / 7200 V) according to UL 758 - File No.: E101965.
  • cUL approval (CSA 180 °C / 7200 V) according to C22.2 No. 210 - File No.: E101965.
  • Compliance with tests described according to IEC 60092-350/354/360, IEC 60331-11/21, IEC 60332-1-1/2, IEC 60332-3-22 category A and IEC 60754-2.
  • Horizontal flame according to UL approval.
  • FT1 and FT2 flame ratings according to cUL approval.

Options

  • Flexible red copper conductor - class 5 according to IEC 60228: consult us
  • Flexible or extra-flexible conductor in silver-plated or nickel-plated copper - class 5 or 6 according to IEC 60228: consult us.
  • Without reinforcement braid: consult us.
  • Impregnated synthetic fibre reinforcement braid: consult us.
  • Very high temperature fibre reinforcement braid: consult us.
  • Multicore cable consisting of the assembly of several single-core SILICOUL® Style 3663 7.2 KV cables: consult us.
  • Other colours: consult us.
  • Other metric or American nominal sections: consult us.
  • Other options and/or combinations of options: consult us.

Use

  • Internal wiring of electric motors where high cut and abrasion resistance is required, transformers, electrical machines.
  • Static machine wiring.
  • Shipbuilding and Railway Construction.
  • Electrical panels.

Technical specifications

Service temperature
-60°C +180°C
Nominal tension
7.2 kV
Test voltage
15 kV