Construction features

TREATED, NON-IMPREGNATED GLASS FIBRE BRAIDED SHEATHING

Continuous service temperature: -60°C +300°C
Peak temperature: +350°C (a few minutes)
General characteristics:
  • Good thermal shock resistance
  • Excellent ageing resistance in hot atmosphere
  • Good weathering resistance: UV, ozone, oxygen
  • Good resistance to usual chemicals
Electrical characteristics:
  • Dry dielectric strength: > 800 V
Standard production:
  • Colour: brown

Standards and approvals

  • IEC 60684-1 and 60684-2

Options

  • Other diameters: consult us
  • Tailor-made sheathing: consult us
  • Double braid sheath: GT 2dielectric strength > 1.5 kV
  • Triple braid sheath: GT 3dielectric strength > 2.0 kV

Use

  • Wiring of heating elements.
  • Protection of cable bundles subject to high temperatures and mechanical stress.
  • Industrial electrothermic machines (ovens, stoves ...)

 

Packing

  • Diameters from 0.5 to 10 mm: 100 m reels
  • Diameters > 10 mm: consult us

Technical specifications

Service temperature
-60°C +300°C
Peak temperature
+350°C