Construction features

Cable composition:

  • Tin-plated copper conductor - class 5 - EN 60228.
  • Separator tape (optional).
  • Elastomer Fire resistant - type EI 104 to EN 50264-2-1.
  • Tinned Copper Braid.
  • Fire resistant elastomer - type EM 104 to EN 50264-2-1.
Continuous service temperature: -40°C to +90°C

Electrical characteristics:

  • Rated voltage: 0.6/1 kV
  • Test voltage: 3.5 kV A.C

Mechanical characteristics:

  • Shear resistance: ★★★★★
  • Abrasion resistance: ★★★★☆
  • Minimum internal bending radius (EN 50355): 10xD
Chemical characteristics:
  • Acid and basic resistance: ★★★★☆
  • Resistance to mineral oils: ★★★★☆
  • Fuel resistance only for M-class: ★★★★☆

Standards and approvals

  • EN 60228, EN 50264-1, EN 50264-2-1.
  • EN 50267-2-1, EN 50267-2-2.
  • EN 60332-1-2, EN 60332-3-24, EN 61034-2.
Fire-smoke
  • Halogen-free (EN 50267-2-1).
  • Low toxicity (EN 50267-2-2).
  • Low smoke (EN 61034-2).
  • Flame retardant (EN 60332-1-2, EN 60332-3-24).

Options

PRODUCT ON ORDER ONLY

Technical specifications

Service temperature
-40°C +90°C
Nominal tension
0.6/1 kV
Test voltage
3.5 kV