Construction features

Armoured naval cable, 0.6/1 KV - Halogen-free

Continuous service temperature: -30°C to +80°C
  • Maximum conductor temperature: +90°C
  • Maximum short-circuit conductor temperature: +250°C

Minimum bending radius: 6 x D

  • Conductor: Red Copper - Class 2 - according to IEC 60228
  • Insulation: cross-linked polyethylene - Type HF XLPE
  • Separator tape
  • Red Copper Braid Armour
  • Outer sheath: HFFR cross-linked compound, type SHF1
Electrical characteristics :
  • Rated voltage: 600/1000V
  • Test voltage: 3500V
Standard production:
  • Outer sheath: black
  • Identification of conductor colours: see technical specification
  • Outer mark: MULTIMAX CF BL 0.6/1kV
    90C IEC 60332-3-22 .

Respected standards

Standards and approvals

  • Not fire propagating according to IEC 60332-3-22.
  • Flame-retardant according to IEC 60332-1-2.
  • Halogen-free according to IEC 60754-1.
  • No corrosivity of fumes according to IEC 60754-2.
  • Low smoke opacity according to IEC 61034.
  • Dimensions according to IEC 60092-353.
  • Production and testing according to IEC 60092-350.
  • BVM certification

Options

  • Flex Series: Class 5 tinned copper conductor + tinned copper armature

Use

  • Fixed installation on board ship

Packing

Hanks, reels

Technical specifications

Service temperature
-30°C to +80°C
Peak temperature
+90°C
Nominal tension
600/1000 V
Test voltage