Construction features

Naval cable

Fire resistant and halogen-free

Continuous service temperature: -30°C to +80°C
  • Maximum conductor temperature: +95°C
  • Maximum short-circuit conductor temperature +250°C

Minimum bending radius: 8 x D

Cable construction
  • Red copper conductor, class 2 according to IEC 60092-376
  • Insulation: fire resistant elastomer
  • Electrical screen: aluminium/PET tape + continuity wire
  • Separator tape
  • HFFR compound outer sheath type SHF1
Electrical characteristics:
  • Nominal voltage: 150/250V
  • Test voltage: 1500V
Standard production:
  • Outer sheath: orange
  • Identification of conductor colours: see technical specification
  • Outer mark: - MULTIMAX 150/250V
    95C IEC 60331- (120) IEC 60332-3-22

 

Respected standards

Standards and approvals

  • Fire resistant according to IEC 60331-1 or IEC 60331-2: 120 minutes.
  • Not fire propagating according to IEC 60332-3-22.
  • Flame-retardant according to IEC 60332-1-2.
  • Halogen-free according to IEC 60754-1.
  • Non-corrosiveness of fumes according to IEC 60754-2.
  • Low opacity of smoke emission according to IEC 61034-
  • Production and testing according to IEC 60092-376 and IEC 60092-350.
  • BVM certification

Options

  • Flex series: flexible tinned copper conductor class 5 according to IEC 60092-376
  • Cross-linked HFFR compound outer sheath, type SHF2

Use

  • Fixed installation on board ship

Packing

Hanks, reels

Technical specifications

Service temperature
-30°C to +80°C
Peak temperature
+95°C
Nominal tension
150/250 V
Test voltage
1500 V
Bending Radius Static
8 x cable outer Ø