Construction features

MULTIMAX CI FIXED INSTALLATION ON BOARD SHIP IEC 60092-350 AND IEC 60092-376
NOT FIRE-PROPAGATING 60332-3-22 - NOT FLAME-PROPAGATING 60332-1

1 Red copper conductor class 2, IEC 60092-376
2 HF XLPE
3 Polyester tape
4 Aluminium/Polyester tape with drainage wire
5 Polyolefin SHF1 sheathing

Respected standards

Standards and approvals

- Halogen-free according to IEC 60754-1
- Fire-retardant according to IEC 60332-3-22
- Flame-retardant according to IEC 60332-1
- Non-corrosiveness of smoke according to IEC 60754-2
- Low smoke opacity : IEC 61034
- BVM and RINA certification nr. ELE283210CS/003

Options

Options: Flex Series Tin-plated copper class 5

Use

Fixed installation on board ship fabrication and testing IEC.60092-350 and IEC 60092-376

Packing

Hanks, reels cardboard drums

Technical specifications

Service temperature
-30°C to +80°C
Nominal tension
150/250 V
Test voltage
1500 V
Bending Radius Static
8 x cable outer Ø