Halogen-Free ARMED Fire-Resistant Naval Cable
Service temperature: -30°C to +80°C
- Maximum conductor temperature: +95°C
- Maximum short-circuit conductor temperature: +250
Minimum bending radius: 6 x D
- Conductor: Red copper - Class 2 according to IEC 60228
- Insulation: Fire-resistant elastomer
- Separator tape
- Armour: Red Copper Braid
- HFFR compound outer sheath, type SHF1
Electrical characteristics:
- Rated voltage: 600/1000V
- Test voltage: 3500V
Standard production:
- Outer sheath: orange
- Identification of conductor colours: see specification
- Outer mark - MULTIMAX CF BL 331 0.6kV
95C IEC 60331- (120) IEC 30332-3-22
- Fire resistant according to IEC 60331-1 or IEC 60331-2: 120 minutes.
- Not fire propagating according to IEC 60332-3-22.
- Flame-retardant according to IEC 60332-1-2.
- Halogen-free according to IEC 60754-1.
- Non-corrosiveness of smoke according to IEC 60754-2.
- Low opacity of fumes emitted according to IEC 61034.
- Dimensions according to IEC 60092-353.
- Production and testing according to IEC 60092-350.
- BVM certification.
- Flex Series - Class 5 tinned copper conductor according to IEC 60228 + braided tinned copper armour.
- Outer sheath made of cross-linked HFFR compound, type SHF2.
- Fixed installation on board ship
- Wiring of fire detection control systems - detection fire
Hanks, reels cardboard drums
Service temperature-30°C to +80°C
Peak temperature+95°C
Nominal tension600/1000 V
Test voltage3500 V
Reaction to FireIEC 60331-21
Bending Radius Static6 x cable Ø ext.