Construction features

Continuous service temperature: -60°C +450°C

The cable has excellent resistance to thermal shock and oxidation of the conductor

  • Conductor: Nickel - type 200
  •  Impregnated Glass Fibre Complex
  • Treated Mineral Fibre Braid
Electrical characteristics:
  • Rated voltage: 300/500V
  • Test voltage: 2000V
Standard production:
  • Standard colour: grey
  • Other colours on request including yellow/green.

Respected standards

Standards and approvals

  • Nickel type 200 according to DIN 17753, DIN 17740 and ASTM B160
  • VERITAS certification of approval
    • BV NO. 153552
    • BV NO. 256192.
  • VDE Test Report No. 9296-5950-0001/32YAT F42/sld-Fc

Options

  • Glass fibre insulation for very high temperatures ref. NVS-R (reduced outside diameter)
  • Other nominal sections: consult us
  • Other options: consult us

Use

  • Electric heater power supply.
  • Heating appliances: ovens, cookers
  • Thermoplastics and rubber machines
  • Heavy industry: foundries, steelworks, glassworks, ...
  • Industrial ovens and stoves

Packing

Hanks and reels.

Technical specifications

Service temperature
-60°C +450°C
Nominal tension
300/500V
Test voltage
2000V