Construction features

FIXED INSTALLATION ON BOARD SHIP

MULTIMAX CI BL FIXED INSTALLATION ON BOARD SHIP IEC 60092-350 AND IEC 60092-376
NOT FIRE-PROPAGATING 60332-3-22 - NOT FLAME-PROPAGATING 60332-1

1 Red copper class 2, IEC 60092-376
2 HF XLPE
3 Polyester tape
4 Aluminium/Polyester tape with drainage wire
5 Armour: red copper braid (EG and EI with continuity wire)
6 SHF1 Polyolefin Sheathing

Respected standards

Standards and approvals

- Halogen-free according to IEC 60754-1
- Fire-retardant according to IEC 60332-3-22
- Flame-retardant according to IEC 60332-1
- Non-corrosiveness of smoke according to IEC 60754-2
- Low smoke opacity : IEC 61034
- BVM and RINA certification nr. ELE283210CS/004

Options

FLEX series conductor Class 5 tinned red copper and tinned copper armouring
Individual shield (EI) red copper braid with continuity wire

Packing

Hanks, reels

Technical specifications

Service temperature
-30°C to +80°C
Nominal tension
150/250 V
Test voltage
1500 V
Bending Radius Static
>= 8 x cable outer Ø